Experiment | End date |
Friend | Result | Problem |
Text |
EB063A | 2017-11-01 | Bo Xia | Success | None | None |
EB063B | 2017-11-02 | BO XIA | Success | None | None |
EB063C | 2017-11-03 | BO XIA | Success | None | None |
EC061A | 2017-10-26 | BO XIA | Success | None | None |
EC061A | 2017-10-26 | BO XIA | Success | None | None |
EC061B | 2017-10-27 | BO XIA | Success | None | Sorry, this experiment was successful, but for special reasons, we had to end the experiment 10 minutes ahead of time. |
EC062A | 2017-10-26 | BO XIA | Success | None | None |
EC062A | 2017-10-26 | BO XIA | Success | None | None |
EC062B | 2017-10-27 | BO XIA | Minor failures | None | NO0135 SCAN ,The anteanna track on later because the time is not enough |
EG078F | 2017-10-31 | BO XIA | Success | None | None |
EG078F | 2017-10-31 | BO XIA | Success | None | From UT11: 30 to UT16: 09, because the antenna limit, resulting in the source no0037 and the source no0103 has been lost |
EG078F | 2017-10-31 | BO XIA | Success | None | Because the antenna limit, resulting in source no0037 and source no0103 has been lost |
EG078G | 2017-11-08 | BO XIA | Success | None | None |
EG099A | 2017-10-22 | Bo Xia | Success | None | None |
EG099B | 2017-11-04 | BO XIA at S | Success | None | None |
EM128C | 2017-11-08 | BO XIA | Success | None | None |
EP103F | 2017-11-04 | BO XIA at S | Success | None | None |
EP107A | 2017-11-07 | BO XIA | Success | None | None |
EP107B | 2017-11-09 | BO XIA | Success | None | None |
ES083 | 2017-11-07 | BO XIA | Minor failures | None | The data of the last scan NO.0181 is invalid because of the antenna EL limit. |
EY029 | 2017-11-06 | BO XIA | Minor failures | None | From UT 06:37 to the end of the observation, the EL of the antenna is below our limited point of 7°so that we terminated at that time. |
GV023 | 2017-10-20 | Bo Xia | Success | None | None |
N17C3 | 2017-10-25 | BoXia | Success | None | None |
N17SX1 | 2017-10-19 | Bo Xia | Success | None | None |
EM130A | 2017-11-01 | JIVE | Failure | None | Sent only one linear polarization. All the data should be flagged. |
N17L3 | 2017-10-30 | JIVE | Failure | None | Probably sent only one linear pol. |
EY029 | 2017-11-06 | JIVE | Failure | None | Appears to have sent linears. |
EG078G | 2017-11-08 | JIVE | Minor failures | None | No fringes scan 9 - structure or did not make it to source. Quite strongly affected by RFI sb 0,3 6 |
EG078F | 2017-10-31 | JIVE | Minor failures | None | RFI looks quite bad sb 0,2,6 |
EM130B | 2017-11-02 | JIVE | Failure | None | Recorded only a single linear polarization. |
EG099B | 2017-11-04 | JIVE | Failure | None | Recorded only a single linear polarization. |
EA058B | 2017-10-31 | None | None | None | None |
EP103E | 2017-10-28 | None | None | None | None |
ES084A | 2017-10-29 | None | None | None | None |
N17K2 | 2017-10-29 | None | None | None | None |