EVN feedback tool

Summary for Effelsberg for Session 2017-3

Experiment End date Friend Result Problem Text
EA058B2017-10-31UweSuccessNoneTarget source too low in elevation at start. On source at about 16:30 UT.
EB063A2017-11-01UweSuccessNoneNone
EB063B2017-11-02UweSuccessNoneNone
EB063C2017-11-03UweSuccessNoneNone
EC061A2017-10-26UweSuccessNoneNone
EC061B2017-10-27UweSuccessNoneNone
EC062A2017-10-26UweSuccessNoneNone
EC062B2017-10-27UweSuccessNoneNone
EG078F2017-10-31UweSuccessNoneNone
EG078G2017-11-08UweSuccessNoneNone
EG099A2017-10-22UweSuccessNoneNone
EG099B2017-11-04UweSuccessNoneNone
EM128C2017-11-08UweSuccessNoneNone
EM130A2017-11-01UweSuccessNoneNone
EM130B2017-11-02UweSuccessNoneNone
EP103E2017-10-28UweMinor failuresFSObservations stopped from 1:19 to 5:25 UT. Frozen FS-PC, operator had to wait for a colleagues to get the backup PC running and restarted.
EP103F2017-11-04UweSuccessNoneNone
EP107A2017-11-07UweMinor failuresRECOThe schedule was running and the antenna was fine, but because of the execution of an outdated script the FS had the wrong IP address for the Mark6 recorder and no data was recored until 9 UT. Sorry, human failure!
ES0832017-11-07UweSuccessNoneNone
ES084A2017-10-29UweSuccessWINDNone
EY0292017-11-06UweSuccessNoneNone
GV0232017-10-20UweSuccessNoneNone
N17C32017-10-25UweSuccessNoneNone
N17K22017-10-29UweMinor failuresWINDStarted 45 min late, because of strong wind.
N17L32017-10-30UweSuccessNoneNone
N17SX12017-10-19UweSuccessNoneX-band dual pol. part had swapped pols. until scan 14.
EP107B2017-11-09UweSuccess, , , , , , , , , , , , , , None
EY0292017-11-06JIVEMinor failuresNoneSlope across the band in both pols (dib towards middle).
EC062A2017-10-26JIVEMinor failuresNoneAffected somewhat by the E-series firmware amplitude issue - Slope across band in amplitude, RCP low.
EC062B2017-10-27JIVEMinor failuresNoneAffected somewhat by the E-series firmware amplitude issue - Slope across band in amplitude, RCP low.
EG078G2017-11-08JIVEMinor failuresNoneAffected somewhat by the E-series firmware amplitude issues. Dip in middle of IF both pols (stronger LCP).
EG078F2017-10-31JIVEMinor failuresNoneSlightly affected by amplitude calibration issue. Dip in center of band. Doesn't look too bad.