EVN feedback tool

Summary for Effelsberg for Session 2016-1

Experiment End date Friend Result Problem Text
EA057B2016-03-05UweSuccessNoneNone
EG078D2016-03-06UweMinor failuresRECE WIND LATELate start because of snow fall. Started at 13 UT. No LCP data, because no IF power on LCP!
EG078E2016-03-08UweMinor failuresRECENo LCP data, because no IF power on LCP! Lost 1 hour between 4:16 and 05:16 UT because of sync loss in Fila10g.
EG089C2016-02-24UweMinor failuresNoneNetwork problems disturbed the communication between FS, DBBC and recorder. Some scans between 17 and 17:50 UT were not recorded properly.
EG089D2016-03-04UweMinor failuresWINDStarted observation late due to snow. On source from 14:50 UT onwards.
EG092A2016-03-05UweSuccessNoneNone
EJ016A2016-03-04UweMinor failuresNoneLost LCP channel after 19 UT. No power on IF due to a faulty relay.
EJ016B2016-03-06UweSuccessNoneNone
EM117A2016-02-27UweSuccessNoneNone
EM117B2016-02-28UweSuccessHIGHThe receiver problem in LCP appeared again, Tsys about 200 K in LCP. RCP is fine with 35 K.
EM117C2016-02-29UweSuccessNoneNone
EM117C2016-02-29UweMinor failuresANTA short break from 7:50 to 8:30 UT was required to fix an oil leakage at one of the azimuth drives.
EM117D2016-03-01UweMinor failuresHIGHThe LCP problem is back. Tsys in LCP as high as 200K from 7:30 to 11:30 UT. What is new is that the problem occurred and vanished within an observation. The receiver will be inspected in the lap after the session.
EM119A2016-02-23Uwe BachFailureNoneNo observations because of snow fall.
EM119B2016-02-24UweSuccessNoneNone
EM119B2016-02-24UweSuccessNoneNone
EM119C2016-03-09UweMinor failuresRECENo LCP data, because no IF power on LCP!
EM119D2016-03-10UweMinor failuresRECENo LCP data, because no IF power on LCP!
ES079A2016-02-26UweMinor failuresWINDSnow fall from 10:50 to 12 UT.
EY024B2016-03-08UweMinor failuresRECENo LCP data, because no IF power on LCP!
GF019A2016-02-19Uwe BachSuccessNoneThere was an IF power loss on RCP due to a misbehaving multiplexer between 6 and 7 UT.
GF019B2016-03-07UweMinor failuresRECE WIND HIGHSeveral snow stops: Started late at 1:10 UT, stopped again from 4 to 8 UT and 14:40 to 15:40 UT. No LCP data, because no IF power on LCP!
GM073B2016-02-22Uwe BachMinor failuresWINDFirst half of the time was lost due to strong wind. Observations at Ef started at 8 UT.
N16C12016-02-18Uwe BachMinor failuresANTA faulty relay on the elevation drive delayed the start at Effelsberg. Ef could join only for the last hour of the observations.
N16L12016-03-03UweSuccessNoneNone
N16M12016-02-25UweSuccessHIGHLCP channel is broken, Tsys 120 K vs. 40 K at RCP. The reason is likely in the cooled part of the receiver and cannot be repair shortly. However, today the receiver is fine again. It might be some loose contact or sporadic problem in the cooled part of receiver and we just hope that it stays okay for the weekend.