EVN feedback tool

Feedback for N18SX2

Friend Site Result Problem Text
Roberts Irbene Success , , , , , , , , , , , , , , None
Miguel Sanz Yebes Success , , , , , , , , , , , , , , No known problems.
Shumilova Svetloe Success , , , , , , , , , , , , , , None
Kotlova, Alakova, Sorokovikov Badary Success , , , , , , , , , , , , , , None
Kiselev P. Zelenchukskaya Success , , , , , , , , , , , , , , None
A.Maccaferri Medicina Success , , , , , , , , , , , , , , None
Jonathan Quick Hartebeesthoek Success , , , , , , , , , , , , , , No known problems.
Bo Xia Shanghai Minor failures , , , , , , , , , , , , , , The first to the seventh scan are stripe-free, starting from the 8th scan, the stripes are normal.
Bo Xia Shanghai Minor failures , , , , , , , , , , , , , , The first to the seventh scan are stripe-free, starting from the 8th scan, the stripes are normal.
Li Guanghui Urumqi Success , , , , , , , , , , , , , , Urumqi X band have only RCP,no LCP.
Uwe Effelsberg Failure , FORM, , , , , , , , , , , , , No data recorded. Recording was aborted after 1-8 seconds because of wrong package sizes. Likely a misbehaving Fila10G. The problem is under further investigation. Was solved at the beginning of ET036B.
Blaauw Westerbork Failure , , RECO, , , , , , , , , , , , Only the first few seconds of every scan recorded. Error in jive5ab log seems to be something network related. Restarting fila10g reconfiguring it stop/start schedule did not help.
Jun Yang Onsala Success , , , , , , , , , , , , , , No known problems.
JIVE Westerbork Failure None No fringes at all due to recording issue. Recording would only record the first frame. Later found to be a fila10g issue similar to Ef. Weirdly restarting the fila10g and reconfiguring did not fix the issue initially but did for the next experiment.
JIVE Effelsberg Failure None Similar issue to Wb. In this case reconfiguring the fila10g did fix the problem, but only in time for the next experiment.
JIVE Noto Minor failures None Weak fringes during X-only part but they are there. Receiver band edge is (as expected) reached in the X-band.
JIVE Tianma65 Failure None No fringes during the X-only part fixed by scan 8.
JIVE Urumqi Minor failures None RCP only.