Friend |
Site |
Result |
Problem |
Text |
Peng Li at S |
Urumqi |
Failure |
None |
Because the VEX file is incorrect, the generated PRC file can't be used. |
Daniel Valero at S |
Yebes |
Minor failures |
None |
DBBC low power |
roma at S |
Medicina |
Success |
None |
all scaan recorded. clear sky |
C.Contavalle at S |
Noto |
Minor failures |
RECE FS |
No comment found that indicate fw change needed The right firmware loaded at 7:30 utc |
Zhukova,Podlosinskaya,Lysakova at S |
Badary |
Success |
None |
None |
Slobojaninova N. at S |
Svetloe |
Success |
None |
None |
Kiselev P. at S |
Zelenchukskaya |
Success |
None |
None |
Jonathan Quick at S |
Hartebeesthoek |
Success |
None |
Sources had set for last 3 scans. No other known problems (recorded with v105E firmware). |
Pawel Wolak |
Torun |
Success |
None |
None |
c.contavalle@ira.inaf.it |
Noto |
Minor failures |
None |
None |
Jun Yang |
Onsala |
Success |
None |
No known problems. The dbbc firmware of DDC V105E_1 was used. |
Geert Kuper |
Westerbork |
Minor failures |
TSYS |
All Tsys values '0' due to LO value restriction in rxg file. |
Jonathan Quick |
Hartebeesthoek |
Minor failures |
TSYS |
The V105E firmware has serious 'birdies' which are contaminating the Tsys badly in many channels. |
Uwe Bach |
Effelsberg |
Success |
None |
None |