EVN feedback tool

Feedback for F13K2

Friend Site Result Problem Text
G.maccaferri Medicina Success None Please note that Md recorded only at 12:26, when we realized Md was scheduled. Rtime scan 2 & 6 for Md not available. Mc: all done! No known problems.
Zhukova Badary Success None None
Slobojaninova N. Svetloe Success None None
Ptitcin A. Zelenchukskaya Minor failures SCHED Scans from 0002 to 0004 missed - elevation to high for the site.
Ptitcin A. Zelenchukskaya Minor failures SCHED Scans from 0002 to 0004 missed - elevation to high for the site.
BoXia Shanghai Minor failures FORM formatter to FS time difference 0.5 seconds or greater. we sync the time of mk5b and FS at 12:41:07
Wenjun Yang Urumqi Failure HIGH No fringe here. The reason probably is weather. It is heavy cloudy.
K. Borkowski Torun Success None No known major problems, although there were only weak fringes to Tr and no fringes to Td. Reason for lack of sensitivity could be cloudy weather and/or a problem with pointing after recent failure of the elevation drive (the telescope was made usable only shortly before this experiment).
S. Buttaccio Noto Minor failures RECE Only LCP available. Swapped polarization on K band receiver, corrected only at the end of observation.
s.buttaccio Noto Success None Please ignore previous comment, it was related to N13K3.
Michael Lindqvist Onsala Success None No known problems.
Elizaveta Rastorgueva-Foi Metsahovi Failure RECE ANT LCP channel in RX is broken (oscillates). Presumably, wrong antcon offsets caused observations off-source
BoXia Shanghai Minor failures FORM formatter to FS time difference 0.5 seconds or greater. we sync the time of FS at 12:41:07