EVN feedback tool

Feedback for F10C1

Friend Site Result Problem Text
Monari Medicina Success None None
Bo Xia Shanghai Success None None
Michael Lindqvist Onsala Minor failures None Very foggy. Problem with MPI-0606. Unstable green lights on the Mark5, flickering while recording. The same pack was used in eb039fon, see comments. Will not use that for 1 Gbps recording. But is a 6 TB pack with about 70% free :-(.
Pablo de Vicente Yebes Success None No known problems
Uwe Bach Effelsberg Success None None
Geert Kuper Westerbork Success None 12 tescopes in array. No known problems.
K. Borkowski Torun Minor failures None Succeeded to repair the C-band receiver virtually the last minute. The sensitivity seems as in the past. Unfortunately there were no noise diode signals! As there were nice fringes we decided to continue this experiment and get to repair the diode afterwards.
P. Cassaro Noto Success None None
alastair gunn Jodrell_Bank Success None No known problems.
alastair gunn Cambridge Success None Kn on BBCs 1 and 2. No known problems.