EVN feedback tool

Feedback for EP051

Friend Site Result Problem Text
Michael Lindqvist Onsala Minor failures WIND We had to stop observing at 07:40 UT due to high wind speeds.
Andrea Orlati Medicina Minor failures None Antenna was not tracking the sources due to an error in Antenna Control Unit configuration. Problem fixed at 0:30 UT.
A. Kraus Effelsberg Minor failures FORM RECO Severe formatter communication problems all through the experiment; unclear how this affects data quality. Several attempts to improve the situation (check communication or use spare formatter) did not work (but led to a loss of a few minutes of data each time). Due to a Mark5 failure no recording was done between UT2326-2346 (reboot was necessary). Some RFI in the lower bands.
Kaz Borkowski Torun Minor failures None Around 1:30 UTC BBC5 lost 1pps and remained so throughout the rest of this experiment (later this bbc unit has been replaced for a spare one, so that the following exps are not affected).
Tony Foley Westerbork Minor failures None Wb phased array (ZP). Bad RFI about 1620MHz. System restart lost array from 01:43-01:50UT
Alastair Gun Jodrell_Bank Success None The Lovell Telescope was used. No known problems.
Alastair Gunn Cambridge Minor failures ANT VLBA rack was running with failing PSU from the start, which may have resulted in unlocked BBCs. It was almost certainly dead by 09:30 UT and was taken offline at 11:43 UT for repair. Schedule was left to run with no valid data.
Esther Moll Robledo Minor failures HIGH RFI POIN VC#5 (294.49MHz) degraded by L-band known RFI. VC#1 (230.49MHz) and VC#3 (262.49MHz) were less affeted. Due to a encoder problem, the antenna was operated in computer mode instead of the usual mode. Pointing was checked before the observation. gps-fmout value at 02:35:13UT : 2005.301.02:35:13.03/gps-fmout/+7.641E-007