EVN feedback tool

Feedback for EM072B

Friend Site Result Problem Text
A.Maccaferri Medicina Minor failures RECO ANT POIN Mk5 module failure, lost scans from 10:05UT to 10:55 ut possible pointing problem, pointing error 0.004 to 0.009 from 17:12 ut to 18:40 ut, restarted acu, so lost scan from 18:35 to 18:40
Wenjun Yang Urumqi Minor failures None There is warning message"Mark5A Warning: Recording throttled(can't keep up)"and error message"Mark5A (error) Error: 1003 Recording throttled(can't keep up)" in Mark5A machine, halt the Exp and replace I/O board of mark5A, but the situation is same. We talked about this with Jun Yang, finally, the skd file was modified by Jun, 2bit change to 1bit. Drudge again and make snp and prc file, and continue observeing, no warning and error message, recording is ok. From UT13:45 to UT14:31, UT 17:35 to UT
Michael Lindqvist Onsala Success None Apart from RFI. No known problems
Bo Xia Shanghai Success None None
Kaz Borkowski Torun Success RFI No known problems except RFI.
Uwe Bach Effelsberg Success None None
Geert Kuper Westerbork Success None Wb used in phased array mode. Apart from RFI no known problems.
Alastair Gunn Jodrell_Bank Success None The Lovell Telescope was used (Jb1). No known problems.
P. Cassaro Noto Success RECO Observation stopped for four minutes just before 13:00 UT due to MK5 problems