EVN feedback tool

Feedback for EM058B

Friend Site Result Problem Text
Michael Lindqvist Onsala Success None Higher than normal Tsys in LCP. Holds for other 5cm-exp. also. Not sure why (yet). Otherwise no known problems.
Kaz Borkowski Torun Failure ANT Not observed due to failure of a resolver in one of the azimuth drives.
Tony Foley Westerbork Minor failures None Single dish was used. Please change the coordinates in the vexfile accordingly. BBC1 was unstable - so Tsys will be hard to calibrate
Uwe Bach Effelsberg Minor failures None Some minutes between 20:29-20:39 UT not on source
Alastair Gunn Jodrell_Bank Success None The MkII telescope was used (Jb2). No known problems.
Alastair Gunn Cambridge Success None No known problems.
P. Cassaro Noto Success None None