Friend |
Site |
Result |
Problem |
Text |
Miguel Sanz |
Yebes |
Success |
None |
None |
Miguel Sanz |
Yebes |
Success |
None |
None |
K. Borkowski |
Torun |
Success |
None |
No known problems. |
Andrea Orlati |
Medicina |
Minor failures |
RECO |
bank switch failed due to bad mark5 module, lost scans from 54 to 63. Antenna sometimes off source for first 1 or 2 seconds. |
Geert Kuper |
Westerbork |
Success |
None |
None |
Zabavskaya N. |
Zelenchukskaya |
Success |
None |
None |
Sergeev R. |
Badary |
Failure |
FORM RECO |
Scans 0022-0040 missed because of problems with the MARK5. Time error 2sec since scan 0097 Time error 8sec since scan 0118 Two channels lost since scan 0118 |
Michael Lindqvist |
Onsala |
Failure |
WIND |
Could only observe until 01:30 UTC, after that to much wind. |
Uwe Bach |
Effelsberg |
Success |
None |
Receiver was cool again. No known problems. |
Peng Li |
Urumqi |
Success |
None |
None |
Jonathan Quick |
Hartebeesthoek |
Minor failures |
RECE RECO |
The RCP channel of the IF distributor has a sticky programmable attenuator causing dropouts after Tsys measurements on multiple scans at 01:07, 02:07, 02:47, 03:01, 03:22, 03:52, 04:32 and 04:52. The recording starting at 02:47 was also truncated due to the operator forgetting to load the next disk pack in time. |
Bo Xia |
Shanghai |
Success |
None |
None |
Alastair Gunn |
Jodrell_Bank |
Success |
None |
No known problems. |