EVN feedback tool

Feedback for EH016A

Friend Site Result Problem Text
yangwj Urumqi Minor failures RECE TSYS LATE The cooling receiver is fail,so we changed to use old non-cooling receiver.so useful recording start at UT 12:11 .T-cal values in log file are wrong, real T-cal value is 174.5K.
A.Maccaferri Medicina Minor failures FS Incorrect setting of IFD at start, corrected after few seconds from start, so first tsys for vc02 and vc04 are wrong.
K.Borkowski Torun Failure RECO Our P&G recorder is still unusable; the struggle continues.
Jonathan Quick Hartebeesthoek Success None None
Michael Lindqvist Onsala Success None No known problems.
A. Kraus Effelsberg Success None None
Alastair Gunn Jodrell_Bank Success None No known problems.
P. Cassaro Noto Success None None
Tony Foley Westerbork Success RECO This was recorded onto mark5 as the capstan motor of the tape drive was being repaired using cannibalized parts from an old Honeywell drive