EVN feedback tool

Feedback for EG072B

Friend Site Result Problem Text
L. Papaleo Noto Minor failures POIN lost some scan at 18:04 to 18:20 for antenna soft limit
Mingfei Gao Urumqi Success None None
Mingfei Gao Urumqi Success None At UT 00:00,the source reached limit position,so we stop observation.
g.nicotra Noto Success None None
A.Mattana Medicina Success None SUCCESS
A.Mattana Medicina Success None SUCCESS
A.Mattana Medicina Success None SUCCESS
K. Borkowski Torun Success None No known problems.
Georgi Effelsberg Minor failures None 1 h late source too deep and outher problems
Stepanova I. Svetloe Minor failures FS Scans no0096-no0103, no0203-no0218, no0223-no0230 failed due to LAN problems.
Ptitcin A. Zelenchukskaya Success None Scans no0031-no0086 missed due to participation in intensive geo session
Zhukov Badary Success None From 18:41 to 20:45 break for observation intensive geo session.
Michael Lindqvist Onsala Failure None Due to a power failure a unit we use before the DBBC got stuck at maximum attenuation. We most likely have had to low IF-level into the DBBC during the experiment.
Geert Kuper Westerbork Success None None
Jonathan Quick Hartebeesthoek Minor failures FORM RECO Multiple clock errors in Mark5B, originating from VSI4 board in terminal, causing jumps in/total loss of scans 163, 167, 171, 187, 191, 201, 215 and from 231 to the end (~2hours in total). Additional jumps may have gone undetected.