EVN feedback tool

Feedback for EG037B

Friend Site Result Problem Text
Antao Shanghai Minor failures RECE The the IF power from left_polarize receiver is changing much that we can detect from the spectrum analizer.But right is OK.
Zhang hua Urumqi Success None None
Zacchiroli Medicina Success None None
Tony Foley Westerbork Minor failures RFI PHAS Wb used in phased array mode. Very severe RFI at the lower end of the band, in particular around 1625MHz. This gave problems with phasing the array there, so the polarization for first band will be poor. Also the phased array had to be restarted, so we lost 16:47-16:58UT
Michael Lindqvist Onsala Success None RFI. Otherwise no known problems.
K.Borkowski Torun Minor failures FS Between about 16:15 and 17:37 UTC data will be mostly lost due hang-up of antenna control computer (probably connected with the thunderstorm at that very time) and later (at ~17:10) an unexpected crash of FS.
A. Polatidis Effelsberg Success None None
Tony Foley Westerbork Minor failures RECO Wb used in phased array mode. Two scan_checks showed errors: 2007.157.19:40:43.07/scan_check/5,eg037b_j1340+3754_no0078,mark4,64,2007y157d19h26m42.004s,838.2s,16.000000,83968 2007.157.22:38:22.88/scan_check/16,eg037b_j1221+4411_no0133,mark4,64,2007y157d22h30m41.834s,458.4s,16.000000,4
Tao An Shanghai Minor failures RECE TSYS HIGH An accessory in the Lband-LCP receiver is aged, resulting extreme variations in the receiver temperature. This problem influenced the whole experiment (EG037B).
P. Cassaro Noto Success None None