EVN feedback tool

Feedback for EF017

Friend Site Result Problem Text
Li Peng at S Urumqi Success None None
Andrea Orlati at S Medicina Success None nothing to report
Michael Lindqvist at S Onsala Minor failures None A few errors/problems in the log: 2006.328.22:29:38.39?ERROR m5 -104 mk5cn: time-out on mk5 device, connection closed 2006.328.23:24:56.44?ERROR m5 -104 mk5cn: time-out on mk5 device, connection closed ---> could not do scan_check and 2006.329.01:19:25.23/scan_check/150,ef017_j0603+2159_no0173,mark4,64,2006y329d1h13m22.125s,?,?,?
Tony Foley Westerbork Success None Wb used in phased array mode. No known problems
A. Polatidis Effelsberg Minor failures RECO Lost UT 0110-0200 due to communications failure with the Mark5 unit. Otherwise OK
Tony Foley Westerbork Minor failures RECO Wb used in phased array mode. Scan_check does not give zero errors for no0053 and no0200; scan_check/2,ef017_j0603+2159_no0053,mark4,64,2006y328d21h18m29.082s,359.1s,16.000000,79872 scan_check/97,ef017_j0603+2159_no0200,mark4,64,2006y329d2h8m47.087s,?,?,?
K. Borkowski Torun Success None No known problems.
Jonathan Quick Hartebeesthoek Success None No known problems
P. Cassaro Noto Minor failures ANT From the beginning till about 00:00 UT observation lost due to problems with the active surface.