EVN feedback tool

Feedback for EB052E

Friend Site Result Problem Text
G.Maccaferri Medicina Success None no known problems
Geert Kuper Westerbork Success None None
Pawel Wolak Torun Success None None
Daniel Valero Yebes Success None No known problems
Carlo Migoni Sardinia Success TSYS LATE The Fila10G was resynchronized at around 07:00UT
Uwe Effelsberg Success None None
Jonathan Quick Hartebeesthoek Success POIN Antenna tracking degraded slightly - later traced to a faulty relay
Jun Yang Onsala Minor failures None Had a power failure. After that, the plc server was not available. The commands of switching noise source on and off were failed to run. There were no useful data in the experiment.
Jun Yang Onsala Success None A correction in the last sentence: No useful Tsys data in the experiment.