| Friend | Site | Result | Problem | Text |
|---|---|---|---|---|
| Geert Kuper | Westerbork | Success | RFI | Wb used in phased array mode. Only RT7 in array. RFI in 1610 MHz USB and 1642 LSB (both RCP and LCP) |
| scalambra | Medicina | Success | None | None |
| Tapasi Ghosh | Arecibo | Minor failures | SCHED POIN | (1) The telescope motion control system wasn't responding to drive commands at the start of the observation. Software restart of several systems were needed. Good data are available from UT 22:07 onwards. (2) For 3C454.3, extra attenuation had to be added to get acceptable power level. Discard data between 22:46 -- 22:52. (3) For the calibrator, J2139+1423, not enough time was allocated for the telescope to reach it. Discard data between 22:50 and 23:00. |
| Tapasi Ghosh | Arecibo | Minor failures | None | CORRECTION: Item(30 above. Discard data between 22:50 -- 23:00 (scan of J2139+1423) |
| Tapasi Ghosh | Arecibo | Success | None | I am having a bad typing day. That time range in item # 3 should be 22:58 -- 23:00 (and NOT 22:50 -- 23:00) Sorry |
| Kaz Borkowski | Torun | Minor failures | None | Operator stopped observations after 23:27 considering the altitudes of remaining sources to be too low. |
| Uwe Bach | Effelsberg | Success | None | None |
| Michael Lindqvist | Onsala | Minor failures | None | Rain + 1 bad scan_check. Strange problem with the noisediode. |
| P. Cassaro | Noto | Success | None | No known problems |
| Alastair Gunn | Jodrell_Bank | Success | None | The Lovell Telescope was used (Jb1). No known problems. |
| Bob Campbell | JIVE | Success | None | correlated in four passes, each with a subset of 2 SBs, to provide the desired number of lags. |