| Friend | Site | Result | Problem | Text |
|---|---|---|---|---|
| Michael Lindqvist | Onsala | Success | None | No known problems. |
| Tony Foley | Westerbork | Minor failures | None | Wb used in phased array mode. One telescope in the array (RT0) was not operating correctly, so there may be a slight reduction in sensitivity Otherwise OK. |
| A. Polatidis | Effelsberg | Minor failures | None | There were no data on VC05. The video converter was exchanged for another one but the problem persisted. We are still investigating. Otherwise no known problems. |
| Andrea Orlati | Medicina | Success | None | All ok. |
| Tony Foley | Westerbork | Minor failures | PHAS | Wb used in phased array mode. For some reason there is no sign of observing the second source (4C39.25) in the array output. I am very puzzled. |
| Wenjun Yang | Urumqi | Failure | RECE | The compressor of C-band doesn't working. |
| Wenjun Yang | Urumqi | Failure | RECE | The compressor of C-band doesn't working. |
| Bo Xia | Shanghai | Success | None | None |
| K. Borkowski | Torun | Minor failures | None | JIVE has detected swapped polarizations. This was corrected immediately. |
| Tony Foley | Westerbork | Minor failures | PHAS | Wb used in phased array mode. Problem found for 4C39.25; the fringe pointing was done correctly, but the telescopes never moved off DA193. We have not yet found the cause, but a disk on our fileserver died last night and has been behaving oddly for a few days. We are reconfiguring and restarting all systems now (1 Jun 08UT) |
| P. Cassaro | Noto | Success | None | None |