| Friend | Site | Result | Problem | Text |
|---|---|---|---|---|
| C.Bortolotti | Medicina | Minor failures | None | Lost part of scan from 09:38:26 to 09:41:12 for antenna slewing - rfi in observed band |
| C. Nocita | Noto | Minor failures | HIGH | Tsys high from beginning of experiment to 9:50:22 due to low power output from local oscillator. Problem fixed not other known problems. |
| Geert Kuper | Westerbork | Success | None | None |
| Daniel Sastre Walter | Yebes | Minor failures | WIND | Strong wind. We had to stop the experiment at 12:45 UTC. |
| K. Borkowski | Torun | Minor failures | FS | BBC07 unlocked throughout this experiment. Between 8:18 and 8:30 UTC telescope could have been off source due to hang-up of Field System. |
| Jun Yang | Onsala | Success | None | Tsys increased significantly (2-4x) after 12:30 UT likely associated with the bad weather (rain). |