EVN feedback tool

Feedback for EL079B

Friend Site Result Problem Text
mmost:hh.vlbif Hartebeesthoek Minor failures TSYS Tsys still unreliable. Subsequently traced to a bad switching signal cable. No other known problems, par from the usual RFI.
mmost:jun-yang Onsala Success Noticed many transient off-source events due to old mechanical system.
mmost:wb.richard_blaauw Westerbork Success OK
mmost:mc.operator Medicina Minor failures spike in gps-fmout window (from 11 to 22 us) at 1550UT. Spike in dbbc delay went to 122461 from 61980. Sync at 1953UT. sync also dbbc. 2003UT sched restarted. missing data from scan 108 to 111 (1957UT-2007UT)
mmost:pawel_wolak Torun Success No known problems.
mmost:ef.uwe_bach Effelsberg Success no known problems