| Friend | Site | Result | Problem | Text |
|---|---|---|---|---|
| Miguel Sanz | Yebes | Success | None | None |
| Miguel Sanz | Yebes | Success | None | None |
| K. Borkowski | Torun | Success | None | No known problems. |
| Andrea Orlati | Medicina | Minor failures | RECO | bank switch failed due to bad mark5 module, lost scans from 54 to 63. Antenna sometimes off source for first 1 or 2 seconds. |
| Geert Kuper | Westerbork | Success | None | None |
| Zabavskaya N. | Zelenchukskaya | Success | None | None |
| Sergeev R. | Badary | Failure | FORM RECO | Scans 0022-0040 missed because of problems with the MARK5. Time error 2sec since scan 0097 Time error 8sec since scan 0118 Two channels lost since scan 0118 |
| Michael Lindqvist | Onsala | Failure | WIND | Could only observe until 01:30 UTC, after that to much wind. |
| Uwe Bach | Effelsberg | Success | None | Receiver was cool again. No known problems. |
| Peng Li | Urumqi | Success | None | None |
| Jonathan Quick | Hartebeesthoek | Minor failures | RECE RECO | The RCP channel of the IF distributor has a sticky programmable attenuator causing dropouts after Tsys measurements on multiple scans at 01:07, 02:07, 02:47, 03:01, 03:22, 03:52, 04:32 and 04:52. The recording starting at 02:47 was also truncated due to the operator forgetting to load the next disk pack in time. |
| Bo Xia | Shanghai | Success | None | None |
| Alastair Gunn | Jodrell_Bank | Success | None | No known problems. |