Feedback for EK028B
| Friend | Site | Result | Problem | Text |
|---|---|---|---|---|
| Michael Lindqvist | Onsala | Failure | ANT | Mechanical problems. |
| Bo Xia | Shanghai | Success | None | None |
| PengLi | Urumqi | Success | None | None |
| Kaz Borkowski | Torun | Success | None | No known problems. |
| Andrea Orlati | Medicina | Success | None | None |
| Uwe Bach | Effelsberg | Success | None | None |
| Geert Kuper | Westerbork | Minor failures | FORM | Wb used in phased array mode. Mark5B formatter gave error 'Mark5B sync error gt_3' This was solved at 16:49. We missed from 15:57 till 16:22 UT, because fmset did not work properly during recording. Had to stop the schedule to resync. |
| P. Cassaro | Noto | Minor failures | RECO | Recording problems. Lost the first 5 scans. |