| Friend | Site | Result | Problem | Text |
|---|---|---|---|---|
| G.Maccaferri | Medicina | Success | None | No known problems. Some RFI as usual. |
| Atvars Nikolajevs | Irbene | Success | None | No known problems |
| Daniel Valero | Yebes | Success | None | Not known problems |
| Bo Xia | Tianma65 | Minor failures | TSYS | NOISE SOURCE PROBLEM |
| Jonathan Quick | Hartebeesthoek | Success | None | No known problems. |
| Uwe | Effelsberg | Minor failures | None | Calibration is only a guess from theory (noise diode is not working), RCP might be broken. |
| Lysenkova M. | Zelenchukskaya | Success | None | None |
| Isaenko O. | Svetloe | Success | None | None |
| Slepkova | Badary | Success | None | None |
| Wenjun Yang | Urumqi | Success | None | None |
| Jun Yang | Onsala | Success | None | None |
| Blaauw | Westerbork | Success | None | None |
| Pawel Wolak | Torun | Success | None | None |
| P.Cassaro | Noto | Success | None | NKP |
| JIVE | Effelsberg | Failure | None | RCP is broken (very weak phases). Tsys information is not reliable. |
| JIVE | Tianma65 | Minor failures | None | Tsys information is not reliable due to a broken noise source. |
| JIVE | Zelenchukskaya | Minor failures | None | RCP appears to be ~ half the power of LCP. Phases look ok. There appear to be some phase jumps - see eg098b-ampphase-P-zc.ps |
| JIVE | Westerbork | Minor failures | None | Has bad weights ~0.6 only (see eg098b-weights.ps). Hence cutoff was set as 0.4 to not delete all Wb data. |